APPLICATION:

It is used to detect leakage of water from the tubes of closed air circuit Water cooled (CACW) cooler mounted on A.C. Motors.

SPECIFICATIONS : 

  1. Temperature Range : Up to 55o Centi.
  2.  Nominal Frequency : 50/60 Hz 
  3.  Rated Voltage : 240 V.AC.

SCOPE:

Water Leakage Detector (WLD) senses the presence of water leaked in a tray from the tubes of water cooler . The two sensing elements of the probe are electrically connected through water and negligible current in micro amps starts flowing between them which is amplified by monitoring unit and an electromagnetic relay inside monitoring unit energizes . The said relay gets de-energized when probe is uncovered by water.